55 Mason St
San Francisco permit 202010106291 · Tenderloin
Voluntary seismic upgrade of steel horizontal bracing system installed below (e) floor framing levels 2-6. 14 units will be converted to %100 accessible apts. remaining 120 housing units receive interior finish upgrades. 6 units to receive communication devices. common area and mep upgrades as well.
- Filed
- Oct 10, 2020
- Issued
- Sep 3, 2021 (11 months after filing)
- Completed
- Sep 20, 2023 (25 months after issuance)
- Review stops
- 12 stops across 6 departments
- Comments issued
- Not recorded for this permit
- Put on hold
- 7 times
The city lists the review stops for this permit but not their results, so we can't tell whether reviewers asked for changes.
| Review stop | Arrived | Finished | Result |
|---|---|---|---|
Central Permit Bureau Building Inspection · CPB | Oct 10, 2020 | Oct 13, 2020 | — |
Permit Processing Center Building Inspection · PPC | Oct 13, 2020 | Jul 30, 2021 | — |
Disability access review Mayor's Office on Disability · MOD | Oct 14, 2020 | Jun 21, 2021 | — |
Zoning review Planning · CP-ZOC | Oct 14, 2020 | May 10, 2021 | — |
Building plan review Building Inspection · BLDG | Nov 11, 2020 | Jun 24, 2021 | — |
Mechanical and energy plan review Building Inspection · MECH | Nov 11, 2020 | May 7, 2021 | — |
Fire prevention review Fire Department · SFFD | Nov 11, 2020 | Jun 30, 2021 | — |
Street use and mapping Public Works · DPW-BSM | Nov 11, 2020 | Jul 27, 2021 | — |
Public Utilities Commission review Public Utilities · SFPUC | Nov 11, 2020 | Jun 29, 2021 | — |
Electrical plan review Building Inspection · MECH-E | Nov 20, 2020 | Jul 2, 2021 | — |
Central Permit Bureau Building Inspection · CPB | Jul 30, 2021 | Sep 3, 2021 | — |
Building Inspection 417-86 | Aug 12, 2021 | Aug 27, 2021 | — |
Source: DataSF 87xy-gk8d (Building Permit Addenda with Routing), retrieved Nov 6, 2026. Reviewer names and notes are left out.
- Permit type
- Additions alterations or repairs
- Status
- Complete
- Estimated cost
- $12,000,000
| Name | Role | License on permit |
|---|---|---|
| Eric S Robinson Paulett Taggart Architects | Architect | C28139 |
| Jeff Brink Dci Engineers | Engineer | S6142 |
San Francisco Department of Building Inspection, the official record
- DataSF Building PermitsAddress, scope, cost, dates and statusRetrieved Nov 5, 2026
- DataSF Building Permit ContactsArchitects and engineers named on the permitRetrieved Nov 5, 2026
- DataSF Building Permit Addenda with RoutingPlan review stops and resultsRetrieved Nov 6, 2026
- Google Street ViewStreet photoTaken Jun 2025