2201 16th Av
San Francisco permit 202112285112 · West of Twin Peaks
This permit revises or supplements an earlier permit, so it is not counted in permit totals or timing.
Revision to pa #202012030195, structural addendum includes addition of plywood shearwall at gridline 8, epoxy holdown in lieu of cast-in-place, and minor structral member changes; item 18b and 24e required for special inspection
- Filed
- Dec 28, 2021
- Issued
- Dec 28, 2021 (within 1 month of filing)
- Completed
- Sep 21, 2022 (9 months after issuance)
- Review stops
- 3 stops across 1 department
- Comments issued
- Not recorded for this permit
The city lists the review stops for this permit but not their results, so we can't tell whether reviewers asked for changes.
| Review stop | Arrived | Finished | Result |
|---|---|---|---|
Intake Building Inspection · INTAKE | Dec 28, 2021 | Dec 28, 2021 | — |
Building plan review Building Inspection · BLDG | Dec 28, 2021 | Dec 28, 2021 | — |
Central Permit Bureau Building Inspection · CPB | Dec 28, 2021 | Dec 28, 2021 | — |
Source: DataSF 87xy-gk8d (Building Permit Addenda with Routing), retrieved Nov 6, 2026. Reviewer names and notes are left out.
- Permit type
- OTC alterations permit
- Status
- Complete
- Estimated cost
- $1
| Name | Role | License on permit |
|---|---|---|
| Michael P Ford Peters Design-Build | Designer | 36260 |
| Nate Williams Mosswood Engineering | Engineer | C62068 |
San Francisco Department of Building Inspection, the official record
- DataSF Building PermitsAddress, scope, cost, dates and statusRetrieved Nov 5, 2026
- DataSF Building Permit ContactsArchitects and engineers named on the permitRetrieved Nov 5, 2026
- DataSF Building Permit Addenda with RoutingPlan review stops and resultsRetrieved Nov 6, 2026
- Google Street ViewStreet photoTaken Apr 2025