173 Downey St
San Francisco permit 202506259462 · Haight Ashbury
Renovate kitchen. renovate 3 bathrooms. add (1) new bathroom on 3/f and (1) half bath on 2/f. new elevator, new radiant heating at all 3 floors. new air conditioning at 3/f.
- Filed
- Jul 31, 2025
- Issued
- Dec 8, 2025 (4 months after filing)
- Completed
- Not completed yet
For comparison, San Francisco permits with the same review (full plan review) filed in 2025 typically took 5 months to be issued (median of 642 issued permits).
- Review stops
- 26 stops across 5 departments
- Comments issued
- 8 times, by Building Inspection, Fire Department
| Review stop | Arrived | Finished | Result |
|---|---|---|---|
Intake Building Inspection · INTAKE | Jun 25, 2025 | Jun 25, 2025 | Administrative |
Zoning review Planning · CP-ZOC | Jun 25, 2025 | Jun 25, 2025 | Not Applicable |
Permit Center Permit Center · PERMIT-CTR | Jul 10, 2025 | Jul 18, 2025 | Approved |
Central Permit Bureau Building Inspection · CPB | Jul 31, 2025 | Jul 31, 2025 | Administrative |
Building plan review Building Inspection · BLDG | Jul 31, 2025 | Aug 27, 2025 | Issued Comments |
Structural plan approval Building Inspection · PAD-STR | Jul 31, 2025 | Sep 3, 2025 | Issued Comments |
Mechanical and energy plan review Building Inspection · MECH | Jul 31, 2025 | Aug 29, 2025 | Issued Comments |
Fire prevention review Fire Department · SFFD | Jul 31, 2025 | Aug 5, 2025 | Issued Comments |
Public Utilities Commission review Public Utilities · SFPUC | Jul 31, 2025 | Aug 7, 2025 | Approved |
Permit Processing Center Building Inspection · PPC | Jul 31, 2025 | Nov 21, 2025 | Administrative |
Building plan review quality control Building Inspection · BLDG-QC | Aug 27, 2025 | Aug 27, 2025 | Approved |
Fire prevention review Fire Department · SFFD | Sep 19, 2025 | Sep 22, 2025 | Issued Comments |
Structural plan approval Building Inspection · PAD-STR | Sep 22, 2025 | Oct 14, 2025 | Issued Comments |
Public Utilities Commission review Public Utilities · SFPUC | Sep 24, 2025 | Sep 24, 2025 | Approved |
Building plan review Building Inspection · BLDG | Oct 2, 2025 | Oct 2, 2025 | Issued Comments |
Fire prevention review Fire Department · SFFD | Oct 7, 2025 | Oct 9, 2025 | Approved-Stipulated |
Structural plan approval Building Inspection · PAD-STR | Oct 15, 2025 | Oct 20, 2025 | Approved |
Fire prevention review Fire Department · SFFD | Oct 22, 2025 | Oct 22, 2025 | Approved-Stipulated |
Public Utilities Commission review Public Utilities · SFPUC | Oct 27, 2025 | Oct 27, 2025 | Approved |
Building plan review Building Inspection · BLDG | Nov 4, 2025 | Nov 4, 2025 | Approved |
Mechanical and energy plan review Building Inspection · MECH | Nov 7, 2025 | Nov 7, 2025 | Issued Comments |
Mechanical and energy plan review Building Inspection · MECH | Nov 18, 2025 | Nov 18, 2025 | Approved |
Building plan review Building Inspection · BLDG | Nov 19, 2025 | Nov 19, 2025 | — |
Fire prevention review Fire Department · SFFD | Nov 19, 2025 | Nov 19, 2025 | Approved-Stipulated |
Public Utilities Commission review Public Utilities · SFPUC | Nov 19, 2025 | Nov 21, 2025 | Approved |
Central Permit Bureau Building Inspection · CPB | Dec 2, 2025 | Dec 8, 2025 | Administrative |
Source: DataSF 87xy-gk8d (Building Permit Addenda with Routing), retrieved Nov 6, 2026. Reviewer names and notes are left out.
- Permit type
- Additions alterations or repairs
- Status
- Issued
- Estimated cost
- $629,000
| Name | Role | License on permit |
|---|---|---|
| David Edward Cumby Cumby Architecture | Architect | C29182 |
| Donald David Double D Engineering | Engineer | S3928 |
San Francisco Department of Building Inspection, the official record
- DataSF Building PermitsAddress, scope, cost, dates and statusRetrieved Nov 5, 2026
- DataSF Building Permit ContactsArchitects and engineers named on the permitRetrieved Nov 5, 2026
- DataSF Building Permit Addenda with RoutingPlan review stops and resultsRetrieved Nov 6, 2026
- Google Street ViewStreet photoTaken Jan 2023